Operation
-
Motor won’t run
Hand turning of coupling is smooth
<Possible cause> <Countermeasure> Failure with motor wiring and electrical equipmentContact the construction contractor and check the wiring status and electrical equipmentMotor failureConsider repairing or repurchasing the motorCoupling bolts not installedAfter checking the rotation direction with motor, install the coupling bolts and start up the pumpReverse rotation of motorRemove all coupling bolts and check the rotation direction of the motor itself.
If rotation direction is opposite, the pump may need to be repaired or parts replaced.Hand turning of coupling is NOT smooth<Possible cause> <Countermeasure> Rotating parts (impeller,etc.) are in contact with other partsDismantle the suction cover and check pump inside. If any contact is found, contact the supplier or access Honda Pumps Web Site “Contact Us”, to request repair the pump or replace the partsClogging of foreign objectDismantle the suction cover and remove foreign objectBearing is damagedRemove the coupling bolts, and rotate the pump and the motor by hand to check for abnormal noise. Contact the supplier or access Honda Pumps Web Site “Contact Us” if the hand turning is not smooth.Freezing inside the pumpDefrost it naturally or warm it up, and check that the inside is completely thawed by hand turning before starting the pump. If the pump is installed in a freezing environment, take the necessary measures on the casing to prevent damage -
Liquid is not pumped
<Possible cause> <Countermeasure> Not priming or Insufficient primingStop the pump, then start up pump again after water priming sufficiently.Insufficient air releaseFully release the air in the piping and start up the pump again.Failure with motor wiring and electrical equipmentContact the construction contractor and check the wiring status and electrical equipmentAir suckingCheck any air sucking caused by forgetting to tighten the joints on the suction piping side or tightening them unevenly.Foreign object inside the suction piping or pumpCheck and remove foreign objectReverse rotation of pumpBefore stopping the operation, make sure that the direction of motor rotation is correct. If it is wrong, contact the construction contractor to check the wiring of motor -
Out of the design operating point
Lack of performance
<Possible cause> <Countermeasure> Foreign object inside the suction piping or pumpCheck the inside of the suction piping (strainer, foot valve, etc.) and remove foreign objectFully opened the discharge valveAdjust the discharge valve towards the specified operating pointLow motor rotation speedCheck for motor overload, frequency, and voltage abnormalities, then keep normal condition.Different motor voltage1) In case motor voltage 400V for equipment voltage 200V,
replace the motor with the correct voltage.
2) In case motor voltage 200V for equipment voltage 400V,
motor shall be damaged.Reverse rotation of pumpBefore stopping the operation, make sure that the direction of motor rotation is correct. If it is wrong, contact the construction contractor to check the wiring of motor
*In case impeller secure to shaft with threaded, pump repair may be required.Pump liquid conditions differ from the orderContact the supplier or access Honda Pumps Web Site “Contact Us”, and ask to reselect a suitable pump.Excessive performance<Possible cause> <Countermeasure> Not satisfied the specified flow rateAdjust the discharge valve towards the specified operating point. Or check the inside of the suction piping.Sudden performance drop<Possible cause> <Countermeasure> Foreign object inside the suction piping or pumpCheck the inside of the suction piping and the pump, and remove foreign object if found. If there is no foreign object and the cause is unknown, contact the supplier or access Honda Pumps Web Site “Contact Us”.Voltage dropCheck and inspect the facility.Abnormally low current value<Possible cause> <Countermeasure> Air pocket inside the piping or the casingFully release the air in the suction piping or the casing, and then start up the pump again.Almost fully opened the discharge valveAdjust the discharge valve towards the specified operating point -
Abnormally high current value
<Possible cause> <Countermeasure> Almost fully opened the discharge valveAdjust the discharge valve towards the specified operating pointRotating parts (impeller,etc.) are in contact with other partsDismantle the suction cover and check pump inside. If any contact is found, contact the supplier or access Honda Pumps Web Site “Contact Us”, to request repair the pump or replace the partsBearing is damagedMeasure the vibration. Contact the supplier or access Honda Pumps Web Site “Contact Us”, if it is difficult to determine.
Abnormal Noise
-
Abnormal noise from the casing
<Possible cause> <Countermeasure> Possibility of cavitation (boiling phenomenon)Check the valve opening, suction height, and vacuum level of the equipment.
Contact the supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improvedRotating parts (impeller,etc.) are in contact with other partsDismantle the suction cover and check pump inside. If any contact is found, contact the supplier or access Honda Pumps Web Site “Contact Us”, to request repair the pump or replace the partsClogging of foreign objectCheck the inside of the suction piping and the pump, and remove foreign object if found. If there is no foreign object and the cause is unknown, contact the supplier or access Honda Pumps Web Site “Contact Us”. -
Abnormal noise from the shaft seal
<Possible cause> <Countermeasure> Insufficient lubrication of mechanical sealStop the pump and check the flow rate and pressure, and then turn the coupling by hand several times. Contact the supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved. -
Abnormal noise from the bearing case
Slight noise at 1 meter from the pump
<Possible cause> <Countermeasure> Hand turning of coupling is smooth when the pump is stopped.
・Insufficient lubrication or Contamination of dust
・Pump running with Insufficient bearing loadIt is no problem if the sound is clear. It may be a temporary noise due to insufficient load on the bearing or contamination of dust. In case noise getting bigger, please contact the supplier or access Honda Pumps Web Site “Contact Us”.Big noise at 1 meter from the pump<Possible cause> <Countermeasure> Hand turning of coupling is not smooth when the pump is stopped.
・Scratches on the bearing surface
・Damage to bearing ballsStop the pump immediately, new bearing replacement necessary. -
Unidentified the noise source
<Countermeasure> Stop the pump immediately, and contact the supplier or access Honda Pumps Web Site “Contact Us”.
Vibration
-
Vibration at the pump side
<Possible cause> <Countermeasure> Excessive pump load due to piping loadCheck the piping connections whether any misalignment (generating execessive load) of flange, please consult the construction contractorFailure of coupling alignmentRefer to “Installation” in the instruction manual. Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved.Failure of installationRefer to “Installation” in the instruction manual. Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved.Possibility of cavitation (boiling phenomenon)Check the valve opening, suction height, and vacuum level of the equipment.
Contact the supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved. -
Vibration at the motor side
<Possible cause> <Countermeasure> Failure of coupling alignmentRefer to “Installation” in the instruction manual. Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved.Failure of installationRefer to “Installation” in the instruction manual. Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved. -
Strong vibration overall
<Possible cause> <Countermeasure> Failure of coupling alignmentRefer to “Installation” in the instruction manual. Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved.Failure of installationRefer to “Installation” in the instruction manual. Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improved.Support of piping on equipment side is insufficientContact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”
Leakage
-
Mechanical Seal
Leaked soon after the starting operation
<Possible cause> <Countermeasure> Failure or malfunction of the mechanical sealStop the pump and check the leaking condition by hand turning. Contact the supplier or access Honda Pumps Web Site “Contact Us”, if the leakage is not stopped.Difference in pumping liquidCheck whether there are any change to the liquid specifications from the order. If the liquid specifications have been changed, the mechanical seal design shall be reselected.Leaked more than one year after the starting operation<Possible cause> <Countermeasure> Leakage due to wear of partsIf the pump has been operated more than one year, maintenance recommended. Contact the supplier or access Honda Pumps Web Site “Contact Us”. -
Gland Packing
Leaked heavily (scattering)
<Possible cause> <Countermeasure> Insufficient adjustment of leakage amountTighten the adjusting nut slowly and evenly to adjust the appropriate amount of leakage. Refer to “Operation and Start-up” in the instruction manualWear of the gland packingIf the pump has been operated more than one year, maintenance recommended. Contact the supplier or access Honda Pumps Web Site “Contact Us”.No leakage (Smoked and heated)<Possible cause> <Countermeasure> Too much tightening of the gland packingUntighten the adjusting nut and adjust to the proper amount. Refer to “Operation and Start-up” in the instruction manual. Contact the supplier or access Honda Pumps Web Site “Contact Us”, if the leakage amount cannnot be adjusted. -
Bearing Case
<Possible cause> <Countermeasure> Abnormality of the sealing part of the bearing case (leakage of lube oil)If the pump is operated as is for a long period of time, it may malfunction. Stop the pump immediately, and contact the supplier or access Honda Pumps Web Site “Contact Us”. -
Wetted parts (casing, suction cover)
<Possible cause> <Countermeasure> Abnormality of the casing and the suction cover(Corrosion, Erosion, etc.)If the pumping liquid leaks from the defective part, take first aid measures using a special putty or others. And contact the supplier or access Honda Pumps Web Site “Contact Us” for repair or replacement. -
Fitting part of the casing, suction cover
<Possible cause> <Countermeasure> Sudden change of liquid temperatureThe mounting bolts of the pressure part may stretch and loosen due to thermal expansion. After the liquid temperature rises, retighten the bolts (hot bolting). Refer to “Operation and Start-up” in the instruction manual.Malfunction of the gasket or O-ringContact the supplier or access Honda Pumps Web Site “Contact Us”. -
Motor
<Possible cause> <Countermeasure> Liquefaction of greaseIt can be continued the operation. If it observed an abnormal noise, contact the supplier or access Honda Pumps Web Site “Contact Us”. -
Flange
<Possible cause> <Countermeasure> Defective or deteriorated the gasket or O-ringReplace the gland packing with a new one.Uneven tightening of the bolt/nutStop the pump, loosen the bolts/nuts of jointed part, and then retighten them evenly.
Overheating
-
Overheating of wetted parts (casing, suction cover)
<Possible cause> <Countermeasure> Rotating parts (impeller,etc.) are in contact with other partsDismantle the suction cover and check pump inside. If any contact is found, contact the supplier or access Honda Pumps Web Site “Contact Us”, to request repair the pump or replace the partsThe flow rate is too high or too lowCavitation (boiling phenomenon) may occur.
Adjust the discharge valve towards the specified operating point.The discharge side is in a shutoff condition.Shut-off operation may result in pump damage.
Adjust the discharge valve towards the appropriate flow rate/pressure. -
Overheating of the sealing parts
Overheating of the gland packing
<Possible cause> <Countermeasure> Over tightening of the gland packingUntighten the adjusting nut and adjust to the proper amount. Refer to “Operation and Start-up” in the instruction manual. Contact the supplier or access Honda Pumps Web Site “Contact Us”, if the leakage amount cannnot be adjusted.Insufficient of the flushing water pressureRefer to the “Utility List” submitted by the supplier and adjust the pressure/amount of flushing water to proper level.Insufficient leakage amountAdjust the leakage to the appropriate amount.Overheating of the mechanical seal<Possible cause> <Countermeasure> Dry running (The sealing face does not be filmed by sufficient liquid)Vent the air sufficiently.
Make sure that air is not sucking into the pump during operation.(Dry running may cause the seal damage).Insufficient of the flushing water pressure/flowRefer to the “Utility List” submitted by the supplier and adjust the pressure/amount of flushing water to an appropriate level. -
Overheating of the bearing part (Bearing case)
Heavy vibration
<Possible cause> <Countermeasure> Deterioration of the lube oil, Contamination of water, etc into the lube oilReplace the lube oil.(Recommended interval : 500 hours after starting operation and every 6 months thereafter)Installation failureRefer to “Installation” in the instruction manual.
Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improvedHigh force by suction and/or discharge pipingCheck the piping connections. If there is any misalignment (generating execessive load), please consult the construction contractorAlignment failureRefer to “Installation” in the instruction manual.
Contact the construction contractor/supplier or access Honda Pumps Web Site “Contact Us”, if the situation is not improvedNon heavy vibration<Possible cause> <Countermeasure> Insufficient amount of lube oil or Improper amount of low quality greaseReplace the lube oil.
(Recommended interval : 500 hours after starting operation and every 6 months thereafter)
For replacement of the grease, contact the supplier or access Honda Pumps Web Site “Contact Us”. -
Overheating of the motor
Too much load on the motor
<Possible cause> <Countermeasure> Rotating parts (impeller,etc.) are in contact with other partsDismantle the suction cover and check pump inside. If any contact is found, contact the supplier or access Honda Pumps Web Site “Contact Us”, to request repair the pump or replace the partsThe flow rate is too highCavitation (boiling phenomenon) may occur.
Adjust the discharge valve towards the specified operating point.<Possible cause> <Countermeasure> Voltage droppedCheck and inspect the facility.
Others
-
Inquiries of maintenance, replacement
<Countermeasure> Contact the supplier or access Honda Pumps Web Site “Contact Us”. -
Any trouble not covered in this trouble shooting section
<Countermeasure> Access Honda Pumps Web Site “Contact Us”. -
Question about pump operation
<Countermeasure> Access Honda Pumps Web Site “Contact Us”. -
Recommended lube oil and amount
<Possible cause> <Countermeasure> Motor Rotation Speed: More than 2900 (2 Pole)TYPE: ISO VG32 TURBIN OILMotor Rotation Speed: Less than 1750 (4,6,8 Pole)TYPE: ISO VG46 TURBIN OILModel HRG, HRO (Liquid Temp. less than 80℃), Model GLNS (Over 2 Pole)TYPE: ISO VG32 TURBIN OILModel HRG, HRO (Liquid Temp. more than 80℃)TYPE: ISO VG68Model ROHTYPE: ISO VG68<Countermeasure> Oil AmountMax : Upper edge of red circle in Oil Gauge
Min : Lower edge of red circle in Oil Gauge